BlueSeal SE
Feel the freedom with BlueSeal









BlueSeal SE

Feel the freedom with BlueSeal
Based on its revolutionary fully sealed BlueSeal magnet, BlueSeal SE lets you experience more productive¹ helium-free MR operations. The BlueSeal SE delivers superb image quality, with up to 80% higher sharpness⁷, even for challenging patients, and performs MRI exams up to 3x faster² with SmartSpeed Precise accelerations for all anatomies. Fast overall exam-time is further achieved by simplifying patient handling at the bore with the guided patient setup. Furthermore, the BlueSeal SE offers an immersive audio-visual experience to help calm patients and guide them through MR exams.

Clinical image gallery

  • L Spine STIR
    L Spine STIR
  • Abdomen Ssh T2
    Abdomen Ssh T2
  • Ankle PD TSE
    Ankle PD TSE
  • L Spine T2 TSE
    L Spine T2 TSE
  • Liver T2 TSE
    Liver T2 TSE
  • Knee  Sag T2 SPAIR
    Knee Sag T2 SPAIR
  • Ankle PD FS TSE
    Ankle PD FS TSE
  • C Spine T1
    C Spine T1
Features
Provide an immersive visual experience
Designed to offer a relaxing sensory experience, Ambient Experience provides positive distractions for patients by incorporating dynamic lighting, projection and sound, contributing to a positive, engaging environment to benefit quality of care. From the moment a patient is moved into the scanner, through completion of the scan, the In-bore Connect solution can help patients to relax, follow directions and minimize motion.
Provide an immersive visual experience
Philips for a lifetime support
Take advantage of remote serviceability, AI-enabled predictive maintenance, frequent system updates, perpetual coil replacement, and tailored financing to help improve uptime and manage your total cost of ownership for the life of your system.
Philips for a lifetime support
Forget about helium with BlueSeal magnet
Philips BlueSeal uses a new micro-cooling technology which requires only a negligible amount (less than 0.5% of today’s volume¹) of liquid helium for cooling. This fraction of the usual amount of liquid helium is placed in the magnet during manufacturing and then fully sealed. As a result, no liquid helium can escape³, either suddenly during a loss of field or gradually.


Specifications
  • Sealed magnet system
    Field strength
    1.5T
    Bore design
    70 cm
    Magnet weight
    2,050 kg* (4,520 lbs) *typical weight
    Typical homogeneity V-RMS
    ≤ 0.9 ppm (at 45 cm DSV)
    Micro-cooling technology
    Yes
    Maximum FOV
    55 cm
    Type of magnet controllers
    Digital, adaptive intelligent
    Cryogen boil-off rate
    Not applicable, fully sealed
    Vent pipe requirements
    Not applicable, fully sealed
  • Omega gradients
    Max. amplitude for each axis
    33 mT/m
  • Omega gradients
    Max. slew rate for each axis
    120 T/m/s
  • RF Receive
    Number of independent receive channels
    Channel independent
    Location of analog-to-digital converter (ADC)
    Inside the coil, close to receive elements
    Signal chain from coil to reconstructor
    Fully digital
    dStream
    Yes
  • Siting information
    Minimum siting requirement
    3.4 x 5.3 m
    Ceiling height (minimum)
    2.56 m
  • SmartWorkflow
    Guided exam set-up
    Yes
    Auto patient centering
    Yes
    Touchless respiratory-triggering
    Yes
    In-room exam start
    Yes
    ScanWise Implant
    Yes
    Automated planning and scanning
    Yes
    Automated patient coaching
    Yes
    Automated post-processing
    Yes


Related products

  • BlueSeal XE Feel the freedom with BlueSeal
    Based on its revolutionary fully sealed BlueSeal magnet, BlueSeal XE lets you experience more productive¹ helium-free MR operations. The BlueSeal XE delivers superb image quality, with up to 80% higher sharpness⁷, even for challenging patients, and performs MRI exams up to 3x faster² with SmartSpeed Precise accelerations for all anatomies. Fast overall exam-time is further achieved by simplifying patient handling at the bore with the guided patient setup. Furthermore, the BlueSeal XE offers an immersive audio-visual experience to help calm patients and guide them through MR exams.
Disclaimer
1. Compared to the Ingenia 1.5T ZBO magnet.
2. Compared to Philips SENSE imaging.
3. Even in the rare case of the magnet becoming unsealed, the negligible amount of helium escaping would not materially affect the oxygen in the room.
4. Compared to conventional zero boil off and sealed 1.5T systems in the industry. Based on published product data..
5. Reconstruction technology consisting of a first AI engine applied at the source of signal (Adaptive CS-NET) and a second AI engine applied on the raw complex imaging data (Precise Net).
6. On average, measured across a sample of sited from Philips MR Installed Base.
7. Compared to Philips SENSE/ C-SENSE imaging.
8. Compared to a workstation.
9. Seamless indicates the workflow is an automatically enabled post-processing step in MR-console. Validation of the AI applications is done by the 3rd party and not by Philips.
10. Workflow refers to steps after completion of data-acquisition to AI processing. No additional user-interaction is required to send data to the External application cloud and to receive reports in PACS.
BlueSeal SE is not yet CE marked, and not available for sale.