The Philips PageWriter TC50 cardiograph is an advanced, reliable, and compact ECG solution, that is easy to use. The TC50 will help you meet your daily demands, giving you time to focus on your patients.

Features
Visual guidance to simplify ECGs
With the PageWriter TC50 cardiograph, each button lights in sequence, prompting you to take an ECG as easily as 1-2-3. The large, 10" touchscreen further streamlines ECGs.
Philips DXL 16-Lead ECG Algorithm expands diagnostic capabilities
Philips DXL 16-Lead ECG Algorithm provides industry-leading ECG interpretations and a suite of advanced STEMI diagnostic aids to provide an interpretation of rhythm and morphology for a wide variety of patient populations. It includes: Critical Values, ST Maps, and culprit artery identification.
Advanced bidirectional network communication for secure connection
Because it’s built on a standard platform, PageWriter TC50 fits seamlessly into your existing IT infrastructure. So you’re always connected, without being locked in. It delivers secure, wireless connectivity via standard LAN protocols to protect the privacy of patient, staff, and financial information.


Specifications
  • Advanced bi-directional network communications
    Central time management (D01)
    Time is manual/auto synced to Network Time Server via IntelliSpace ECG/IntelliBridge Enterprise
  • Orders worklist (D01)
    Download of orders worklist from networked server
    Worklist
    User-configurable drop down lists (e.g., by location, user, or shift)
    Drop Down Lists
    Ad-hoc query for specific orders based upon multiple user-entered or scanned search criteria
    (e.g., patient ID, last/first name)
    Supported by Open Worklist with IntelliSpace ECG and select departmental systems
    Open Worklist Support
    Supported by standard HL7 and DICOM
    HL7 and DICOM Support
    Interfaces via IntelliBridge Enterprise for departmental and hospital systems
    IntelliBridge Enterprise
    Supported by DICOM modality worklist within DICOM MWL system
    DICOM Modality Worklist
  • ADT (D02)
    Query and retrieval of patient demographic information
    Patient demographic information
    Based upon user-entered or scanned search criteria (e.g., patient ID, last/first name)
    Scanned Search Criteria
    Supported by standard HL7 interface via IntelliSpace Enterprise for hospital systems
    Standard HL7 Interface
  • Last ECG
    Automatic retrieval of previous ECG or list of available ECGs for current patient
    Automatic Retrieval
    Supported by IntelliSpace ECG
    IntelliSpace ECG
  • Interactive query
    Automatic retrieval of previous ECG or list of available ECGs for current patient
    Automatic Retrieval
    Supported by TraceMasterVue
    TraceMasterVue Support
  • Manual orders (D07)
    Create patient worklists with complete demographic information for later retrieval
    Create Patient Worklists
  • DICOM ECG result output (D08)
    Create DICOM 12-lead ECG
    12-lead ECG
    Generate DICOM General ECG
    General ECG
  • Signal quality indicators
    Leads-off advisory
    Anatomical lead map displays the location and label of loose or disconnected leads/electrodes
    Lead color
    Four colors to indicate quality of individual leads
    Lead check
    Lead-placement software detects 20 different lead reversals
    Heart rate
    Continuous display of patient heart rate
    Print preview
    Full-screen preview of ECR waveforms prior to printing
  • User training and self help
    Application help
    Integrated graphical help for primary functions
    Self-paced training
    PC-based, interactive, dynamic animation covering all major clinical functions
    Training mode
    Integrated waveform simulation
  • Presentation Filters - 10 sec Reports
    High Pass
    Low Pass
  • User interface
    Touchscreen
    1-2-3 operation, Context-sensitive application, Five-wire, resistive touchscreen
    Keyboard
    Backlit 1-2-3 buttons, 65-button, standard full alphanumeric keyboard, Special characters supported
    Membrane keyboard cover
    Silicone-based flexible cover protects keyboard from particulate and liquid ingress
  • Display
    Size
    10.4 in TFT active matrix
    Resolution
    800 x 600 SVGA
    Colors
    64 colors
  • Patient connections
    Patient Interface Module (PIM)
    Remote microprocessor-controlled
    Digital module provides 5μV resolution
    5μV resolution
    Acquire data at 8,000 samples per second per lead for 12/18 lead ECG
    For 12/18 lead ECG
    Long lead set (H23)
    Extended length lead wires enable greater distances between the PIM and the patient connections
    End connectors (adaptors)
    Adaptors
    Alligator clips (E01)
    Alligator clips for tab electrodes
    Wide tab (E02)
    Flat adaptor for tab electrodes reduces twisting (AAMI only)
    Welsh bulbs (E04)
    Six Welsh bulbs and four limb clamps
    Snap/Tab adaptor (E06)
    Fits both snap and tab electrodes with metal on both sides
  • Printer
    Type
    200dpi (voltage axis) by 500dpi (time axis) at 25mm/sec
    Resolution
    High-resolution, digital-array printer using thermal-sensitive paper
  • Mechanical
    Dimensions
  • Connectivity
    Modem (H11)
    V.90, K56flex, enhanced V.34, V.32bis, V.32, V.22bis and below
    Fax (included in H11)
    Group 3, Class 1 or 2 fax modem protocol
    LAN
    10/100 Base-TX IEEE 802.3 Ethernet via on-board RJ45
    Wireless (D21)
    802.11(b/g), 802.11(i), WPA, WPA2
    Wireless (D22)
    802.11(a/b/g), 802.11(i), WPA, WPA2
    Wireless credential
    Cisco compatible CCX v4
    Internal storage
    200 ECGs
    FIPS certificate
    FIPS 140-2 validated
    External storage
    200 ECGs with optional USB device
  • Automated data input
    Bar code reader (H12)
    Reads code 30 Symbology
    Flexible field data entry
    Data Entry
  • Safety and Performance
    International Standards
    • General Requirement for Safety IEC 60601-1: 1988 +A1:1991 +A2:1995
    • Particular Requirement for Safety of Electrocardiographs
    • IEC 60601-2-25: 1993 + A1:1999
    • Particular Requirements for Safety IEC 60601-2-51: 2003
    • US General Requirements for Safety UL 2601-1: 2003 1997
    • Diagnostic Electrocardiographic Devices AAMI EC11 1991 (R: 2001)
    • General Requirement for Safety and Electromagnetic Compatibility IEC 60601-1-2:2001
    • CAN/CSA-C22.2 No. 601.1-M90 S1:1994 B:1996
  • Smart "IC" card reader (H14)
    ISO 7816 and EMV 3.1.1
    ISO and EMV
    Supports SLE 4418/28 and SLE 4443/42
    SLE Support
  • Pre-processing filters
    AC noise
    50 or 60 Hz
    Signal processing
    Artifact Rejection and Baseline Wander
  • Presentation filters - 10 sec reports
    High pass
    0.05, 0.15 and 0.5Hz
    Low pass
    40, 100 and 150Hz
  • Presentation filters - rhythm
    High pass
    0.05 and 0.15Hz
    Low pass
    40, 100, and 150Hz
  • Electrical
    Battery
    Lithium ion
    Second battery (H15)
    Hot swappable (not printing)
    Operating condition
    No fail operation during ECG printing
    Battery capacity (per battery)
    Typically 30 ECGs or 30 minutes of continuous rhythm recording on a full charge
    Battery recharge
    Four hours per battery to full capacity
    Main power
    100-240VAC, 50/60Hz
    Power consumption
    60W max
    Dimensions
    31 x 40 x 11cm (12 x 16 x 4in)
    Weight includes
    Includes battery, patient module, lead wires, alligator clips, electrode pack, and paper pack
    Weight
    9.8kg (21.6lb)
  • Environmental
    Operating conditions - Temperature
    10° to 40°C (50°F to 104°F)
    Operating conditions - Humidity
    10% to 90% relative humidity (noncondensing)
    Operating conditions - Altitude
    Up to 3,000m (10,000ft) altitude
    Storage conditions - Temperature
    -20°C to 50°C (-4°F to 122°F)
    Storage conditions - Humidity
    10% to 90% relative humidity (noncondensing)
    Storage conditions - Altitude
    Up to 4,550m (15,000ft)


Documentation