PageWriter Cardiograph

PageWriter TC50

Cardiograph

860310

Find similar products

The Philips PageWriter TC50 cardiograph is an advanced, reliable, and compact ECG solution, that is easy to use. The TC50 will help you meet your daily demands, giving you time to focus on your patients.

Features
Visual guidance

Visual guidance to simplify ECGs

With the PageWriter TC50 cardiograph, each button lights in sequence, prompting you to take an ECG as easily as 1-2-3. The large, 10" touchscreen further streamlines ECGs.
Philips DXL 16-Lead ECG Algorithm

Philips DXL 16-Lead ECG Algorithm expands diagnostic capabilities

Philips DXL 16-Lead ECG Algorithm provides industry-leading ECG interpretations and a suite of advanced STEMI diagnostic aids to provide an interpretation of rhythm and morphology for a wide variety of patient populations. It includes: Critical Values, ST Maps, and culprit artery identification.
Advanced bidirectional network communication

Advanced bidirectional network communication for secure connection

Because it’s built on a standard platform, PageWriter TC50 fits seamlessly into your existing IT infrastructure. So you’re always connected, without being locked in. It delivers secure, wireless connectivity via standard LAN protocols to protect the privacy of patient, staff, and financial information.
Automated reporting sequence

Automated reporting sequence saves time

The high performance PageWriter TC50 cardiograph features an automated ECG report sequence with integrated wireless transfer of ECGs to streamline your workflow.
Lead placement aids

Lead placement aids accurate placement of leads on the patient

The anatomic patient interface module and LeadCheck help support correct lead placement, while the 3-in-1 Trident lead wires reduce tangling.
Critical Value statements

Critical Value statements speed the delivery of urgent care

When appropriate, the PageWriter TC70 automatically displays Critical Value summary statements boldly on screen and on printed ECG reports so that caregivers can determine the need for urgent care. Clinicians can quickly take action and reduce the time from the discovery of a critical cardiac event to intervention, such as balloon angioplasty.
Saved ECGs

Saved ECGS can be quickly accessed

Clinicians can save time by retrieving previous ECGs at the bedside for quick comparisons.
  • Visual guidance
  • Philips DXL 16-Lead ECG Algorithm
  • Advanced bidirectional network communication
  • Automated reporting sequence
See all features
Visual guidance

Visual guidance to simplify ECGs

With the PageWriter TC50 cardiograph, each button lights in sequence, prompting you to take an ECG as easily as 1-2-3. The large, 10" touchscreen further streamlines ECGs.
Philips DXL 16-Lead ECG Algorithm

Philips DXL 16-Lead ECG Algorithm expands diagnostic capabilities

Philips DXL 16-Lead ECG Algorithm provides industry-leading ECG interpretations and a suite of advanced STEMI diagnostic aids to provide an interpretation of rhythm and morphology for a wide variety of patient populations. It includes: Critical Values, ST Maps, and culprit artery identification.
Advanced bidirectional network communication

Advanced bidirectional network communication for secure connection

Because it’s built on a standard platform, PageWriter TC50 fits seamlessly into your existing IT infrastructure. So you’re always connected, without being locked in. It delivers secure, wireless connectivity via standard LAN protocols to protect the privacy of patient, staff, and financial information.
Automated reporting sequence

Automated reporting sequence saves time

The high performance PageWriter TC50 cardiograph features an automated ECG report sequence with integrated wireless transfer of ECGs to streamline your workflow.
Lead placement aids

Lead placement aids accurate placement of leads on the patient

The anatomic patient interface module and LeadCheck help support correct lead placement, while the 3-in-1 Trident lead wires reduce tangling.
Critical Value statements

Critical Value statements speed the delivery of urgent care

When appropriate, the PageWriter TC70 automatically displays Critical Value summary statements boldly on screen and on printed ECG reports so that caregivers can determine the need for urgent care. Clinicians can quickly take action and reduce the time from the discovery of a critical cardiac event to intervention, such as balloon angioplasty.
Saved ECGs

Saved ECGS can be quickly accessed

Clinicians can save time by retrieving previous ECGs at the bedside for quick comparisons.

Specifications

Safety and Performance
Safety and Performance
International Standards
  • General Requirement for Safety IEC 60601-1: 1988 +A1:1991 +A2:1995
  • Particular Requirement for Safety of Electrocardiographs
  • IEC 60601-2-25: 1993 + A1:1999
  • Particular Requirements for Safety IEC 60601-2-51: 2003
  • US General Requirements for Safety UL 2601-1: 2003 1997
  • Diagnostic Electrocardiographic Devices AAMI EC11 1991 (R: 2001)
  • General Requirement for Safety and Electromagnetic Compatibility IEC 60601-1-2:2001
  • CAN/CSA-C22.2 No. 601.1-M90 S1:1994 B:1996
Advanced bi-directional network communications
Advanced bi-directional network communications
Central time management (D01)
  • Time is manual/auto synced to Network Time Server via IntelliSpace ECG/IntelliBridge Enterprise
Presentation Filters - 10 sec Reports
Presentation Filters - 10 sec Reports
High Pass
Low Pass
Smart "IC" card reader (H14)
Smart "IC" card reader (H14)
Supports SLE 4418/28 and SLE 4443/42
  • SLE Support
ISO 7816 and EMV 3.1.1
  • ISO and EMV
Interactive query
Interactive query
Supported by TraceMasterVue
  • TraceMasterVue Support
Automatic retrieval of previous ECG or list of available ECGs for current patient
  • Automatic Retrieval
Display
Display
Resolution
  • 800 x 600 SVGA
Colors
  • 64 colors
Size
  • 10.4 in TFT active matrix
DICOM ECG result output (D08)
DICOM ECG result output (D08)
Create DICOM 12-lead ECG
  • 12-lead ECG
Generate DICOM General ECG
  • General ECG
Presentation filters - rhythm
Presentation filters - rhythm
High pass
  • 0.05 and 0.15Hz
Low pass
  • 40, 100, and 150Hz
User interface
User interface
Touchscreen
  • 1-2-3 operation, Context-sensitive application, Five-wire, resistive touchscreen
Keyboard
  • Backlit 1-2-3 buttons, 65-button, standard full alphanumeric keyboard, Special characters supported
Membrane keyboard cover
  • Silicone-based flexible cover protects keyboard from particulate and liquid ingress
Last ECG
Last ECG
Supported by IntelliSpace ECG
  • IntelliSpace ECG
Automatic retrieval of previous ECG or list of available ECGs for current patient
  • Automatic Retrieval
Environmental
Environmental
Operating conditions - Altitude
  • Up to 3,000m (10,000ft) altitude
Storage conditions - Altitude
  • Up to 4,550m (15,000ft)
Operating conditions - Humidity
  • 10% to 90% relative humidity (noncondensing)
Storage conditions - Humidity
  • 10% to 90% relative humidity (noncondensing)
Operating conditions - Temperature
  • 10° to 40°C (50°F to 104°F)
Storage conditions - Temperature
  • -20°C to 50°C (-4°F to 122°F)
Mechanical
Mechanical
Dimensions
ADT (D02)
ADT (D02)
Query and retrieval of patient demographic information
  • Patient demographic information
Supported by standard HL7 interface via IntelliSpace Enterprise for hospital systems
  • Standard HL7 Interface
Based upon user-entered or scanned search criteria (e.g., patient ID, last/first name)
  • Scanned Search Criteria
Printer
Printer
Type
  • 200dpi (voltage axis) by 500dpi (time axis) at 25mm/sec
Resolution
  • High-resolution, digital-array printer using thermal-sensitive paper
Patient connections
Patient connections
Snap/Tab adaptor (E06)
  • Fits both snap and tab electrodes with metal on both sides
Patient Interface Module (PIM)
  • Remote microprocessor-controlled
Long lead set (H23)
  • Extended length lead wires enable greater distances between the PIM and the patient connections
Acquire data at 8,000 samples per second per lead for 12/18 lead ECG
  • For 12/18 lead ECG
Welsh bulbs (E04)
  • Six Welsh bulbs and four limb clamps
Wide tab (E02)
  • Flat adaptor for tab electrodes reduces twisting (AAMI only)
End connectors (adaptors)
  • Adaptors
Alligator clips (E01)
  • Alligator clips for tab electrodes
Digital module provides 5μV resolution
  • 5μV resolution
Signal quality indicators
Signal quality indicators
Heart rate
  • Continuous display of patient heart rate
Print preview
  • Full-screen preview of ECR waveforms prior to printing
Lead check
  • Lead-placement software detects 20 different lead reversals
Leads-off advisory
  • Anatomical lead map displays the location and label of loose or disconnected leads/electrodes
Lead color
  • Four colors to indicate quality of individual leads
Pre-processing filters
Pre-processing filters
Signal processing
  • Artifact Rejection and Baseline Wander
AC noise
  • 50 or 60 Hz
Connectivity
Connectivity
LAN
  • 10/100 Base-TX IEEE 802.3 Ethernet via on-board RJ45
Fax (included in H11)
  • Group 3, Class 1 or 2 fax modem protocol
Modem (H11)
  • V.90, K56flex, enhanced V.34, V.32bis, V.32, V.22bis and below
Internal storage
  • 200 ECGs
External storage
  • 200 ECGs with optional USB device
Wireless (D21)
  • 802.11(b/g), 802.11(i), WPA, WPA2
FIPS certificate
  • FIPS 140-2 validated
Wireless (D22)
  • 802.11(a/b/g), 802.11(i), WPA, WPA2
Wireless credential
  • Cisco compatible CCX v4
Manual orders (D07)
Manual orders (D07)
Create patient worklists with complete demographic information for later retrieval
  • Create Patient Worklists
Electrical
Electrical
Weight includes
  • Includes battery, patient module, lead wires, alligator clips, electrode pack, and paper pack
Battery
  • Lithium ion
Dimensions
  • 31 x 40 x 11cm (12 x 16 x 4in)
Main power
  • 100-240VAC, 50/60Hz
Battery capacity (per battery)
  • Typically 30 ECGs or 30 minutes of continuous rhythm recording on a full charge
Weight
  • 9.8kg (21.6lb)
Power consumption
  • 60W max
Operating condition
  • No fail operation during ECG printing
Battery recharge
  • Four hours per battery to full capacity
Second battery (H15)
  • Hot swappable (not printing)
Orders worklist (D01)
Orders worklist (D01)
User-configurable drop down lists (e.g., by location, user, or shift)
  • Drop Down Lists
Ad-hoc query for specific orders based upon multiple user-entered or scanned search criteria
  • (e.g., patient ID, last/first name)
Download of orders worklist from networked server
  • Worklist
Supported by Open Worklist with IntelliSpace ECG and select departmental systems
  • Open Worklist Support
Supported by standard HL7 and DICOM
  • HL7 and DICOM Support
Interfaces via IntelliBridge Enterprise for departmental and hospital systems
  • IntelliBridge Enterprise
Supported by DICOM modality worklist within DICOM MWL system
  • DICOM Modality Worklist
Presentation filters - 10 sec reports
Presentation filters - 10 sec reports
Low pass
  • 40, 100 and 150Hz
High pass
  • 0.05, 0.15 and 0.5Hz
User training and self help
User training and self help
Application help
  • Integrated graphical help for primary functions
Training mode
  • Integrated waveform simulation
Self-paced training
  • PC-based, interactive, dynamic animation covering all major clinical functions
Automated data input
Automated data input
Bar code reader (H12)
  • Reads code 30 Symbology
Flexible field data entry
  • Data Entry
Safety and Performance
Safety and Performance
International Standards
  • General Requirement for Safety IEC 60601-1: 1988 +A1:1991 +A2:1995
  • Particular Requirement for Safety of Electrocardiographs
  • IEC 60601-2-25: 1993 + A1:1999
  • Particular Requirements for Safety IEC 60601-2-51: 2003
  • US General Requirements for Safety UL 2601-1: 2003 1997
  • Diagnostic Electrocardiographic Devices AAMI EC11 1991 (R: 2001)
  • General Requirement for Safety and Electromagnetic Compatibility IEC 60601-1-2:2001
  • CAN/CSA-C22.2 No. 601.1-M90 S1:1994 B:1996
Advanced bi-directional network communications
Advanced bi-directional network communications
Central time management (D01)
  • Time is manual/auto synced to Network Time Server via IntelliSpace ECG/IntelliBridge Enterprise
See all specifications
Safety and Performance
Safety and Performance
International Standards
  • General Requirement for Safety IEC 60601-1: 1988 +A1:1991 +A2:1995
  • Particular Requirement for Safety of Electrocardiographs
  • IEC 60601-2-25: 1993 + A1:1999
  • Particular Requirements for Safety IEC 60601-2-51: 2003
  • US General Requirements for Safety UL 2601-1: 2003 1997
  • Diagnostic Electrocardiographic Devices AAMI EC11 1991 (R: 2001)
  • General Requirement for Safety and Electromagnetic Compatibility IEC 60601-1-2:2001
  • CAN/CSA-C22.2 No. 601.1-M90 S1:1994 B:1996
Advanced bi-directional network communications
Advanced bi-directional network communications
Central time management (D01)
  • Time is manual/auto synced to Network Time Server via IntelliSpace ECG/IntelliBridge Enterprise
Presentation Filters - 10 sec Reports
Presentation Filters - 10 sec Reports
High Pass
Low Pass
Smart "IC" card reader (H14)
Smart "IC" card reader (H14)
Supports SLE 4418/28 and SLE 4443/42
  • SLE Support
ISO 7816 and EMV 3.1.1
  • ISO and EMV
Interactive query
Interactive query
Supported by TraceMasterVue
  • TraceMasterVue Support
Automatic retrieval of previous ECG or list of available ECGs for current patient
  • Automatic Retrieval
Display
Display
Resolution
  • 800 x 600 SVGA
Colors
  • 64 colors
Size
  • 10.4 in TFT active matrix
DICOM ECG result output (D08)
DICOM ECG result output (D08)
Create DICOM 12-lead ECG
  • 12-lead ECG
Generate DICOM General ECG
  • General ECG
Presentation filters - rhythm
Presentation filters - rhythm
High pass
  • 0.05 and 0.15Hz
Low pass
  • 40, 100, and 150Hz
User interface
User interface
Touchscreen
  • 1-2-3 operation, Context-sensitive application, Five-wire, resistive touchscreen
Keyboard
  • Backlit 1-2-3 buttons, 65-button, standard full alphanumeric keyboard, Special characters supported
Membrane keyboard cover
  • Silicone-based flexible cover protects keyboard from particulate and liquid ingress
Last ECG
Last ECG
Supported by IntelliSpace ECG
  • IntelliSpace ECG
Automatic retrieval of previous ECG or list of available ECGs for current patient
  • Automatic Retrieval
Environmental
Environmental
Operating conditions - Altitude
  • Up to 3,000m (10,000ft) altitude
Storage conditions - Altitude
  • Up to 4,550m (15,000ft)
Operating conditions - Humidity
  • 10% to 90% relative humidity (noncondensing)
Storage conditions - Humidity
  • 10% to 90% relative humidity (noncondensing)
Operating conditions - Temperature
  • 10° to 40°C (50°F to 104°F)
Storage conditions - Temperature
  • -20°C to 50°C (-4°F to 122°F)
Mechanical
Mechanical
Dimensions
ADT (D02)
ADT (D02)
Query and retrieval of patient demographic information
  • Patient demographic information
Supported by standard HL7 interface via IntelliSpace Enterprise for hospital systems
  • Standard HL7 Interface
Based upon user-entered or scanned search criteria (e.g., patient ID, last/first name)
  • Scanned Search Criteria
Printer
Printer
Type
  • 200dpi (voltage axis) by 500dpi (time axis) at 25mm/sec
Resolution
  • High-resolution, digital-array printer using thermal-sensitive paper
Patient connections
Patient connections
Snap/Tab adaptor (E06)
  • Fits both snap and tab electrodes with metal on both sides
Patient Interface Module (PIM)
  • Remote microprocessor-controlled
Long lead set (H23)
  • Extended length lead wires enable greater distances between the PIM and the patient connections
Acquire data at 8,000 samples per second per lead for 12/18 lead ECG
  • For 12/18 lead ECG
Welsh bulbs (E04)
  • Six Welsh bulbs and four limb clamps
Wide tab (E02)
  • Flat adaptor for tab electrodes reduces twisting (AAMI only)
End connectors (adaptors)
  • Adaptors
Alligator clips (E01)
  • Alligator clips for tab electrodes
Digital module provides 5μV resolution
  • 5μV resolution
Signal quality indicators
Signal quality indicators
Heart rate
  • Continuous display of patient heart rate
Print preview
  • Full-screen preview of ECR waveforms prior to printing
Lead check
  • Lead-placement software detects 20 different lead reversals
Leads-off advisory
  • Anatomical lead map displays the location and label of loose or disconnected leads/electrodes
Lead color
  • Four colors to indicate quality of individual leads
Pre-processing filters
Pre-processing filters
Signal processing
  • Artifact Rejection and Baseline Wander
AC noise
  • 50 or 60 Hz
Connectivity
Connectivity
LAN
  • 10/100 Base-TX IEEE 802.3 Ethernet via on-board RJ45
Fax (included in H11)
  • Group 3, Class 1 or 2 fax modem protocol
Modem (H11)
  • V.90, K56flex, enhanced V.34, V.32bis, V.32, V.22bis and below
Internal storage
  • 200 ECGs
External storage
  • 200 ECGs with optional USB device
Wireless (D21)
  • 802.11(b/g), 802.11(i), WPA, WPA2
FIPS certificate
  • FIPS 140-2 validated
Wireless (D22)
  • 802.11(a/b/g), 802.11(i), WPA, WPA2
Wireless credential
  • Cisco compatible CCX v4
Manual orders (D07)
Manual orders (D07)
Create patient worklists with complete demographic information for later retrieval
  • Create Patient Worklists
Electrical
Electrical
Weight includes
  • Includes battery, patient module, lead wires, alligator clips, electrode pack, and paper pack
Battery
  • Lithium ion
Dimensions
  • 31 x 40 x 11cm (12 x 16 x 4in)
Main power
  • 100-240VAC, 50/60Hz
Battery capacity (per battery)
  • Typically 30 ECGs or 30 minutes of continuous rhythm recording on a full charge
Weight
  • 9.8kg (21.6lb)
Power consumption
  • 60W max
Operating condition
  • No fail operation during ECG printing
Battery recharge
  • Four hours per battery to full capacity
Second battery (H15)
  • Hot swappable (not printing)
Orders worklist (D01)
Orders worklist (D01)
User-configurable drop down lists (e.g., by location, user, or shift)
  • Drop Down Lists
Ad-hoc query for specific orders based upon multiple user-entered or scanned search criteria
  • (e.g., patient ID, last/first name)
Download of orders worklist from networked server
  • Worklist
Supported by Open Worklist with IntelliSpace ECG and select departmental systems
  • Open Worklist Support
Supported by standard HL7 and DICOM
  • HL7 and DICOM Support
Interfaces via IntelliBridge Enterprise for departmental and hospital systems
  • IntelliBridge Enterprise
Supported by DICOM modality worklist within DICOM MWL system
  • DICOM Modality Worklist
Presentation filters - 10 sec reports
Presentation filters - 10 sec reports
Low pass
  • 40, 100 and 150Hz
High pass
  • 0.05, 0.15 and 0.5Hz
User training and self help
User training and self help
Application help
  • Integrated graphical help for primary functions
Training mode
  • Integrated waveform simulation
Self-paced training
  • PC-based, interactive, dynamic animation covering all major clinical functions
Automated data input
Automated data input
Bar code reader (H12)
  • Reads code 30 Symbology
Flexible field data entry
  • Data Entry