1
0

Shopping cart

There are currently no items in your shopping cart.

    • 2 year warranty

    • 30 days return guarantee

    • Free delivery on orders over £30

    Products

    VAC.CLNR EASYLIFE BAGLESS BASIC IE

    FC8142/61

    Troubleshooting

    My Philips EasyLife vacuum cleaner's suction power is low

    If your Philips EasyLife vacuum cleaner's suction power is low, there might be an easy solution. Discover how to improve its performance.

    See below for all possible causes of a loss of suction power and check if a cause applies to your appliance

    Possible causes and solutions for loss of suction power:

    1. The dust container is full and the filter cone is dirty

    Empty the dust container and clean the filter cone. For optimal performance, empty the dust container and clean the filter cone when the dust container full indicator is switched on.

    Emptying the dust container

    2. The HEPA dust container filter and foam filter are dirty and need to be cleaned

    To maintain optimal performance, clean the HEPA filter each time you empty the dust container. The HEPA dust container filter is attached to the dust container. The dust container foam filter is placed behind the HEPA dust container filter. Both filters can be rinsed under the tap. Let the filters dry completely before you put them back.

    The HEPA filter

    3. The HEPA exhaust filter is dirty and needs to be cleaned

    The HEPA Exhaust filter needs to be cleaned every 6 months. If you clean the filter with water, you can rinse it under the tap up to 4 times before you have to replace it with a new Philips HEPA exhaust filter. The filter needs to be replaced every 2 years.

    The HEPA exhaust filter can be found under the HEPA exhaust filter grille.

    The HEPA exhaust filter

    4. The motor protection filter is dirty and needs to be cleaned

    To maintain optimal performance, clean the motor protection filter at least once a year. The motor protection filter is located in a holder inside the dust container compartment. The filter can be cleaned by shaking it out over a dustbin.

    The motor protection filter

    5. The nozzle, hose or tube are blocked by an object

    Remove any object that is blocking the air passage in the nozzle, hose or tube.

    If the above solution did not help to solve your problem, please contact Philips Consumer Care.

    The information on this page applies to the following models: FC8142/61 , FC8140/60 , FC8144/01 , FC8146/01 . more less